TTFX

Features

Dry type transformer.

All transformers are tropicalized with anti-flash varnish:

  • Protection against corrosive environments.
  • Greater electrical insulation.
  • High compaction power.
  • Noise level reduction.
  • Longer useful life of the product.

Lifting bolts from 10kVA.

Tailor made, if the standard specifications are not what is required.

Applications

  • TTF transformers are used for galvanic isolation of three-phase solar installations.
  • They are also used in the generation of ground-referenced neutrals.

Available accessories

Available accessories

  • One, two and up to three electrostatic screens.
  • Class II.
  • Wheel
  • PT100, PTC or Bimetallic probes.
  • C5 paint.
  • Several RAL
  • Electric temperature panel.
  • Anti-condensation system.
  • IP up to IP-65.

Downloads

Certificates

TTFX0.63 » TTFX1 » TTFX2 » TTFX2.5 » TTFX3.15 » TTFX4 » TTFX5 » TTFX6.3 » TTFX8 » TTFX10 » TTFX12.5 » TTFX16 » TTFX20 » TTFX25 » TTFX31.5 » TTFX40 » TTFX50 » TTFX63 » TTFX80 » TTFX100 » TTFX160 » TTFX200 » TTFX250 » TTFX315 » TTFX400 » TTFX500 » TTFX630 » TTFX800 » TTFX1000 »
Rating 0,63 kVA 1 kVA 2 kVA 2,5 kVA 3,15 kVA 4 kVA 5 kVA 6,3 kVA 8 kVA 10 kVA 12,5 kVA 16 kVA 20 kVA 25 kVA 31,5 kVA 40 kVA 50 kVA 63 kVA 80 kVA 100 kVA 160 kVA 200 kVA 250 kVA 315 kVA 400 kVA 500 kVA 630 kVA 800 kVA 1000 kVA
Input voltage 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N 800 V+N
Output voltage 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Connection group YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0
Protection degree IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Efficiency (%) 88,7 90,5 93,5 94,7 94,7 95,4 95,7 95,8 96,5 96,5 96,7 95,9 96,3 96,6 96,9 94,9 95 95,5 96 96,6 97,2 97,5 98,2 98,2 98,4 98,5 98,6 98,8 99
Noise level (dB) < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 55 < 55 < 55 < 55 < 55 < 55 < 55 < 65 < 65 < 65 < 65 < 65 < 65 < 65
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Standards IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE
Weight 5,9 kg 9,5 kg 20 kg 23,9 kg 27,4 kg 36 kg 40,4 kg 55 kg 67 kg 78 kg 94 kg 105 kg 125 kg 145 kg 162 kg 191 kg 233 kg 277 kg 320 kg 368 kg 560 kg 660 kg 808 kg 1000 kg 1092 kg 1658 kg 2000 kg 2413 kg 2993 kg
Dimensions (AxBxCxDxE) 150x102x183x66x125mm 7Ø 180x94x208x76x150mm 7Ø 240x143x268x125x200mm 9Ø 300x124x330x102x250mm 9Ø 300x134x330x112x250mm 9Ø 300x154x330x132x250mm 9Ø 300x164x330x142x250mm 9Ø 360x145x382x122x300mm 11Ø 360x165x382x142x300mm 11Ø 420x247x366x142x350mm 11Ø 420x267x366x162x350mm 11Ø 480x247x459x115x400mm 11Ø 480x267x459x142x400mm 11Ø 480x287x459x166x400mm 11Ø 480x307x459x168x400mm 11Ø 640x325x550x159,5x426mm 11Ø 640x350x550x179,5x426mm 11Ø 640x370x550x199,5x426mm 11Ø 714x400x637x189x426mm 11Ø 714x420x637x209x426mm 11Ø 760x550x826x460x470mm 13Ø 760x550x826x460x470mm 13Ø 1020x550x1060x460x690mm 13Ø 1083x700x1220x600x690mm 18Ø 1083x700x1220x600x690mm 18Ø 1300x700x1325x600x800mm 18Ø 1300x700x1325x600x800mm 18Ø 1300x700x1325x600x800mm 18Ø 1490x700x1325x600x800mm 18Ø
Quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
Buy Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart
How to buy?

You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden

Related series

TTFW THREE-PHASE ISOLATION TRANSFORMERS FOR SOLAR INVERTERS
TTFW
Rating
From 0,63 kVA to 1000 kVA
Input voltage
800 V+N
Output voltage
400 V+N
Protection degree
IP-23 / IK-08
TTFZ THREE-PHASE ISOLATION TRANSFORMERS FOR SOLAR INVERTERS
TTFZ
Rating
From 0,63 kVA to 1000 kVA
Input voltage
800 V+N
Output voltage
400 V+N
Protection degree
From IP-65 / IK-10 to IP-54 / IK-10

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.