RTF14X

Features

Reactor

Anti-flash varnish finish, offering:

  • Protection against corrosive environments
  • Increase of electrical isolation
  • High compression capacity
  • Reduction of noise level
  • Increase of product's lifespan

​Safety class I

Includes thermal protection against overtemperatures

Possibility of tailor-made manufacturing

Technical remarks about the use of detuned reactors:

  • They avoid resonance between the feeding transformer's inductance and the capacitance of capacitors' bank
  • They eliminate overvoltages and overcurrents either from the transformer and from the capacitors' bank
  • They protect capacitors against harmonics avoiding early aging
  • They limit conection peaks of the capacitors' bank increasing their lifespan and reducing microcuts in the fedding voltage

Downloads

RTF14X5 » RTF14X10 » RTF14X12.5 » RTF14X15 » RTF14X20 » RTF14X25 » RTF14X30 » RTF14X40 » RTF14X50 » RTF14X60 » RTF14X80 » RTF14X100 »
Line voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Capacitor rating 5 kvar (460 V, 50 Hz) 10 kvar (460 V, 50 Hz) 12,5 kvar (460 V, 50 Hz) 15 kvar (460 V, 50 Hz) 20 kvar (460 V, 50 Hz) 25 kvar (460 V, 50 Hz) 30 kvar (460 V, 50 Hz) 40 kvar (460 V, 50 Hz) 50 kvar (460 V, 50 Hz) 60 kvar (460 V, 50 Hz) 80 kvar (460 V, 50 Hz) 100 kvar (460 V, 50 Hz)
Effective rating 4,3 kvar 8,6 kvar 10,8 kvar 12,9 kvar 17,2 kvar 21,6 kvar 25,9 kvar 34,5 kvar 43,1 kvar 51,7 kvar 69,0 kvar 86,2 kvar
Rated current 7,2 A 11,7 A 12,7 A 18,8 A 20,8 A 25,6 A 29,2 A 34,5 A 41,4 A 45,2 A 59 A 72 A
Reactor 18,479 mH (50 Hz) 9,2393 mH (50 Hz) 7,3914 mH (50 Hz) 6,1595 mH (50 Hz) 4,6196 mH (50 Hz) 3,6957 mH (50 Hz) 3,0798 mH (50 Hz) 2,3098 mH (50 Hz) 1,8479 mH (50 Hz) 1,5399 mH (50 Hz) 1,1549 mH (50 Hz) 0,9239 mH (50 Hz)
Inductance tolerance 3% 3% 3% 3% 3% 3% 3% 3% 3% 3% 3% 3%
Resonance frequency 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%) 134 Hz (p 14%)
Harmonic currents I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5% I3 – 10%, I5 – 9%, I7 – 5%
Thermal overload factor 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05 0,05
Frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz
Protection degree IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN AN AN AN AN
Ambient temperature 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC 45ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC
Insulation Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC Clase H – 180 ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Includes Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection Bimetal thermal protection
Standards IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE IEC/EN/UNE-EN 60076-6, CE
Mounting Screws Screws Screws Screws Screws Screws Screws Screws Screws Screws Screws Screws
Weight 7,2 kg 11,7 kg 12,7 kg 18,8 kg 20,8 kg 25,6 kg 29,2 kg 34,5 kg 41,4 kg 45,2 kg 59 kg 72 kg
Dimensions (AxBxCxDxE) 150x150x185x95x100 mm 9Ø 180x155x220x100x120 mm 9Ø 180x160x220x105x120 mm 9Ø 180x195x220x140x120 mm 9Ø 180x205x219,5x150x120 mm 9Ø 180x230x219,75x175x120 mm 9Ø 240x200x320x125x160 mm 9Ø 240x210x320x150x160 mm 9Ø 240x235x320x160x160 mm 9Ø 240x245x320x170x160 mm 9Ø 300x200x365x139x200 mm 9Ø 300x225x365x164x200 mm 9Ø
Quote / Buy Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
How to buy?

You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.

Related series

RTFX THREE-PHASE BLOCKING REACTORS FOR CAPACITOR BANKS P=7%.
RTFX
Protection degree
IP-00
RTF5X THREE-PHASE BLOCKING REACTOR FOR CAPACITOR BANKS P=5.67%
RTF5X
Protection degree
IP-00

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.