C10D.
125 A (Phase) Rated current

C10D. 125 A (Phase) Rated current

C10D125

Technical characteristics

Rated current
125 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08
Cooling
ANAN
Ambient temperature
45 ºC
Temperature rise
Class F – 155ºC
Insulation
Class H – 180ºC
Windings
Class HC – 200 ºC
Test voltage
3 kV (1 min, 50 Hz)
Standards
IEC/EN/UNE-EN 60076|61000-3-2/4, CE y IEE 519, CE
Weight
18,2 kg
Dimensions (AxBxCxDxE)
315x230x315x205x200 mm 6Ø
How to buy?

You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden

Features

Compensator

Anti-flash varnish finish, offering:

  • Protection against corrosive environments
  • Increase of electrical isolation
  • High compression capacity
  • Reduction of noise level
  • Increase of product's lifespan

Metalic box IP-23 enclosure painted with epoxy polyester resin RAL 7035 (cat. C2 ISO 12994-2)

Safety class I

Possibility of tailor-made manufacturing

Technical remarks:

  • Impedance adaptor that complements C20D and C22D series
  • For more information check our compensators' application guide

Downloads

Plans

 Plano de C10D. 125 A (Phase) Rated current

Other references in this series

Rated current
16 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
20 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
25 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
31,5 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
40 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
50 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
63 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
80 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
100 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
125 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
160 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
200 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
250 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
315 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Rated current
400 A (Phase)
Line voltage
400 V
Frequency
50/60 Hz
Protection degree
IP-23 / IK-08

View product »

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.