TTUX
Features
Dry type transformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product’s lifespan
Safety class I
Includes lifting eyebolts from >6,3 kVA
Possibility of tailor-made manufacturing
Applications
- TTU transformers are mainly used to isolate circuits, by raising the voltage from 230V to 400V.
- TTU transformers can be used to increase voltage from 230V to 400V
- In installations with a certain level of electrical noise, the TTU series improves the quality of the secondary electrical network.
Available accessories
- Protections in primary and secondary.
- One, two and up to 3 electrostatic screens.
- Class II
- Wheels.
- PT100, PTC or Bimetallic probes.
- Painting C5.
- Different RAL.
- Temperature control unit
- Anti condensation system
- Different IP up to IP-65
CE certificate
TTUX0.63 » | TTUX1 » | TTUX2 » | TTUX2.5 » | TTUX3.15 » | TTUX4 » | TTUX5 » | TTUX6.3 » | TTUX8 » | TTUX10 » | TTUX12.5 » | TTUX16 » | TTUX20 » | TTUX25 » | TTUX31.5 » | TTUX40 » | TTUX50 » | TTUX63 » | TTUX80 » | TTUX100 » | TTUX125 » | TTUX160 » | TTUX200 » | TTUX250 » | TTUX315 » | TTUX400 » | TTUX630 » | TTUX800 » | TTUX1000 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rating | 0,63 kVA | 1 kVA | 2 kVA | 2,5 kVA | 3,15 kVA | 4 kVA | 5 kVA | 6,3 kVA | 8 kVA | 10 kVA | 12,5 kVA | 16 kVA | 20 kVA | 25 kVA | 31,5 kVA | 40 kVA | 50 kVA | 63 kVA | 80 kVA | 100 kVA | 125 kVA | 160 kVA | 200 kVA | 250 kVA | 315 kVA | 400 kVA | 630 kVA | 800 kVA | 1000 kVA |
Input voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
Output voltage | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N | 400 V+N |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Connection group | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 |
Protection degree | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 |
Cooling | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Clase H – 180 ºC | Class H – 180ºC | Class H – 180ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Clase HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Efficiency (%) | 88,7 | 90,5 | 93,5 | 94,7 | 94,7 | 95,4 | 95,7 | 95,8 | 96,5 | 96,5 | 96,7 | 95,9 | 96,3 | 96,6 | 96,9 | 94,9 | 95 | 95,5 | 96 | 96,6 | 96,8 | 97,2 | 97,5 | 98,2 | 98,2 | 98,4 | 98,6 | 98,8 | 99 |
Noise level (dB) | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 55 | < 55 | < 55 | < 55 | < 55 | < 55 | < 55 | < 55 | < 65 | < 65 | < 65 | < 65 | < 65 | < 65 |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
Certifications | — | — | UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
Weight | 5,9 kg | 9,5 kg | 20 kg | 23,9 kg | 27,4 kg | 36 kg | 40,4 kg | 55 kg | 67 kg | 78 kg | 94 kg | 105 kg | 125 kg | 145 kg | 162 kg | 191 kg | 233 kg | 277 kg | 320 kg | 368 kg | 462 kg | 560 kg | 660 kg | 808 kg | 1000 kg | 1092 kg | 2000 kg | 2413 kg | 2993 kg |
Dimensions (AxBxCxDxE) | — | — | 240x143x268x125x200mm 9Ø | 300x124x330x102x250mm 9Ø | 300x134x330x112x250mm 9Ø | 300x154x330x132x250mm 9Ø | 300x164x330x142x250mm 9Ø | 360x145x382x122x300mm 11Ø | 360x165x382x142x300mm 11Ø | 420x247x366x142x350mm 11Ø | 420x267x366x162x350mm 11Ø | 480x247x459x115x400mm 11Ø | 480x267x459x142x400mm 11Ø | 480x287x459x166x400mm 11Ø | 480x307x459x168x400mm 11Ø | 640x325x550x159,5x426mm 11Ø | 640x350x550x179,5x426mm 11Ø | 640x370x550x199,5x426mm 11Ø | 714x400x637x189x426mm 11Ø | 714x420x637x209x426mm 11Ø | 760x550x826x460x470mm 13Ø | 760x550x826x460x470mm 13Ø | 760x550x826x460x470mm 13Ø | 1020x550x1060x460x690mm 13Ø | 1083x700x1220x600x690mm 18Ø | 1083x700x1220x600x690mm 18Ø | 1300x700x1325x600x800mm 18Ø | 1300x700x1325x600x800mm 18Ø | 1490x700x1325x600x800mm 18Ø |
Quote | |||||||||||||||||||||||||||||
Buy |
How to buy?
You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.