AUTZ
Features
Dry type autotransformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product’s lifespan
IP-65 up to 80kVA and IP-54 as from 100kVA (for IP-65 degree consult us) metallic box enclosure painted with polyester resin RAL 7035 (cat. C4 ISO 12994-2)
Safety class I
Includes silent-blocks, lifting points from 31,5 kVA and cable glands for ratings from 31,5 up to 400 kVA.
Possibility of tailor-made manufacturing
Downloads
| AUTZ1 » | AUTZ2 » | AUTZ3.15 » | AUTZ5 » | AUTZ8 » | AUTZ10 » | AUTZ12.5 » | AUTZ16 » | AUTZ20 » | AUTZ25 » | AUTZ31.5 » | AUTZ40 » | AUTZ50 » | AUTZ63 » | AUTZ80 » | AUTZ100 » | AUTZ125 » | AUTZ160 » | AUTZ200 » | AUTZ250 » | AUTZ315 » | AUTZ400 » | AUTZ500 » | AUTZ630 » | AUTZ800 » | AUTZ1000 » | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rating | 1 kVA | 2 kVA | 3,15 kVA | 5 kVA | 8 kVA | 10 kVA | 12,5 kVA | 16 kVA | 20 kVA | 25 kVA | 31,5 kVA | 40 kVA | 50 kVA | 63 kVA | 80 kVA | 100 kVA | 125 kVA | 160 kVA | 200 kVA | 250 kVA | 315 kVA | 400 kVA | 500 kVA | 630 kVA | 800 kVA | 1000 kVA |
| Input voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
| Output voltage | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N | 230 V+N |
| Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
| Connection group | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 | YN0 |
| Cover | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C4 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C5 ISO 12994-2) |
| Protection degree | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP65 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 | IP54 – IK-10 |
| Cooling | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF | ANAF |
| Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
| Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
| Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
| Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
| Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
| Standards | IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 61558, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
IEC/EN/UNE-EN 60076, CE UL 5085-1 / UL 5085-2 CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06 |
| Certifications | UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
UL RECOGNIZED – CONSTRUCTION ONLY – Component FILE: E532753 |
| Includes | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks | Silent blocks |
| Weight | 17 kg | 23 kg | 34 kg | 53 kg | 60 kg | 65 kg | 73 kg | 83 kg | 95 kg | 106 kg | 126 kg | 141 kg | 180 kg | 202 kg | 215 kg | 285 kg | 328 kg | 363 kg | 429 kg | 474 kg | 591 kg | 757 kg | 1048 kg | 1150 kg | 1447 kg | 1933 kg |
| Dimensions (AxBxCxDxE) | 395x217x408x360x370 mm 10.5Ø | 395x217x408x360x370 mm 10.5Ø | 495x267x608x560x470 mm 10.5Ø | 513x316x778x220x450 mm 13Ø | 513x316x778x220x450 mm 13Ø | 513x316x778x220x450 mm 13Ø | 513x316x778x220x450 mm 13Ø | 613x316x878x220x550 mm Ø13 | 613x316x878x220x550 mm Ø13 | 613x316x878x220x550 mm Ø13 | 745x413x735x370x350 mm 11Ø | 745x413x735x370x350 mm 11Ø | 745x413x735x370x350 mm 11Ø | 745x413x735x370x350 mm 11Ø | 745x413x735x370x350 mm 11Ø | 968x630x1155x500x426 mm 12Ø | 968x630x1155x500x426 mm 12Ø | 968x630x1155x500x426 mm 12Ø | 968x630x1155x500x426 mm 12Ø | 968x630x1155x500x426 mm 12Ø | 1040x892x1374x714x485 mm 18Ø | 1040x892x1374x714x485 mm 18Ø | 1525x1000x1765x806x680 mm 18Ø | 1525x1000x1765x806x680 mm 18Ø | 1525x1000x1765x806x680 mm 18Ø | 2000x1100x1800x900x790 mm 20Ø |
| Downloads | ||||||||||||||||||||||||||
| Quote | ||||||||||||||||||||||||||
| Buy |
How to buy?
You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.