Features
Reactor
Advantages of resin technology:
- Protection against corrosive environments
- Protection against high vibration levels
- Protection against electrodynamic efforts
- Reduction of noise level
- Increase of product’s lifespan
IP-20 enclosure in last generation V-0 fireproof metallic polymer box according to UL94
Safety class I, convertible in class II
Includes thermal protection against overtemperatures
Possibility of tailor-made manufacturing
Technical remarks about the use of line reactors:
- Reduction of the current harmonics generated by the equipment, reducing current consumption and improving power factor
- Reduction of the peak factor of the current wave, increasing equipment’s lifespan
- Attenuation of the microcuts of the feeding voltage produced by the converter, source of the bad functioning of computers, robots and other equipments
Applications
- Single-phase low rating installations where harmonic filtering is required, such as those with non-linear loads, rectifiers, single-phase frequency converters, power supplies, etc.
- Environments with high humidity or corrosion, as well as vibrations and voltage peaks, due to the resin coating.
Downloads
QR2.5 » | QR4 » | QR5 » | QR6.3 » | QR8 » | QR10 » | QR12.5 » | QR16 » | QR20 » | QR25 » | QR31.5 » | |
---|---|---|---|---|---|---|---|---|---|---|---|
Rated current | 2,5 A | 4 A | 5 A | 6,3 A | 8 A | 10 A | 12,5 A | 16 A | 20 A | 25 A | 31,5 A |
Motor rating | 0,23 kW / 0,31 CV | 0,38 kW / 0,5 CV | 0,46 kW / 0,6 CV | 0,55 kW / 0,75 CV | 0,75 kW / 1 CV | 1,1 kW / 1,5 CV | 1,5 kW / 2 CV | 1,85 kW / 2,5 CV | 2,2 kW / 3 CV | 3 kW / 4 CV | 4 kW / 5,5 CV |
Line voltage | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V | 220 – 260 V |
Reactor | 8,785 mH (50 Hz) | 5,491 mH (50 Hz) | 4,393 mH (50 Hz) | 3,486 mH (50 Hz) | 2,745 mH (50 Hz) | 2,196 mH (50 Hz) | 1,757 mH (50 Hz) | 1,373 mH (50 Hz) | 1,098 mH (50 Hz) | 0,879 mH (50 Hz) | 0,697 mH (50 Hz) |
Voltage drop | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) | 3% (50 Hz) |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Protection degree | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 |
Thermal protection | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C | Thermal protection (NC) 120°C |
Cooling | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN |
Ambient temperature | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC |
Temperature rise | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE | IEC/EN/UNE-EN 60076-6, CE |
Mounting | Screws and DIN Rail | Screws and DIN Rail | Screws and DIN Rail | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws |
Weight | 0,8 kg | 0,8 kg | 1,0 kg | 1,6 kg | 1,6 kg | 1,6 kg | 1,6 kg | 2,0 kg | 2,7 kg | 2,7 kg | 3,6 kg |
Dimensions (AxBxCxDxE) | 84x101x98x88x55 mm 5Ø | 84x101x98x88x55 mm 5Ø | 84x101x98x88x55 mm 5Ø | 106x123x122x111x74 mm 5Ø | 106x123x122x111x74 mm 5Ø | 106x123x122x111x74 mm 5Ø | 106x123x122x111x74 mm 5Ø | 106x123x122x111x74 mm 5Ø | 118x138x132x122x88 mm 6Ø | 118x138x132x122x88 mm 6Ø | 136x162x156x146x104 mm 6Ø |
Quote | |||||||||||
Buy |
How to buy?
You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.