TM
TM50 » | TM51 » | TM52 » | TM53 » | TM55 » | TM57 » | TM510 » | TM515 » | TM520 » | |
---|---|---|---|---|---|---|---|---|---|
Rating | 2/5/7,5 VA (Cl. 0,2/0,5/1) | 5/10/15 VA (Cl. 0,2/0,5/1) | 10/15/25 VA (Cl. 0,2/0,5/1) | 15/30/50 VA (Cl. 0,2/0,5/1) | 30/50/75 VA (Cl. 0,2/0,5/1) | 50/75/100 VA (Cl. 0,2/0,5/1) | 50/75/100 VA (Cl. 0,2/0,5/1) | 50/75/100 VA (Cl. 0,2/0,5/1) | 50/75/100 VA (Cl. 0,2/0,5/1) |
Input voltage | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) | 100..500 V (/v3) |
Output voltage | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) | 100..110 V (/v3) |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Protection degree | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 | IP-20 |
Cooling | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Thermal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating | 6 times nominal rating |
Overvoltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage | 1,2 times nominal voltage |
Temperature rise | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE | IEC/EN/UNE-EN 61869-3, CE |
Mounting | Screws and DIN Rail | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws |
Weight | 3,7 kg | 4,7 kg | 5,4 kg | 7,1 kg | 9,1 kg | 10,3 kg | 13,3 kg | 14,8 kg | 16,9 kg |
Dimensions (AxBxCxDxE) | 96x112x116x96x77 mm 6Ø | 108x122x125x106x89 mm 6Ø | 108x122x135x106x89 mm 6Ø | 126x145x147x125x102 mm 7Ø | 126x145x167x125x102 mm 7Ø | 126x145x177x125x102 mm 7Ø | 150x165x180x145x125 mm 7Ø | 150x165x190x145x125 mm 7Ø | 150x165x210x145x125 mm 7Ø |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.