Features

Dry type transformer

Anti-flash varnish finish, offering:

  • Protection against corrosive environments
  • Increase of electrical isolation
  • High compression capacity
  • Reduction of noise level
  • Increase of product's lifespan

Safety class I

Includes electrostatic screen between primary and secondary terminals and bimetallic temperature sensor

Includes also lifting eyebolts from X VA

Possibility of tailor-made manufacturing

Downloads

TTHX1 » TTHX2 » TTHX3.15 » TTHX4 » TTHX5 » TTHX6.3 » TTHX8 » TTHX10 »
Rating 1000 VA 2000 VA 3150 VA 4000 VA 5000 VA 6300 VA 8000 VA 10000 VA
Input voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Output voltage 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Connection group YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0 YNyn0
Protection degree IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Inrush current < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Test voltage 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz) 4,5 kV (1 min, 50 Hz)
No load voltage < 3 % < 3 % < 3 % < 3 % < 3 % < 3 % < 3 % < 3 %
Leakage current 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth)
Standards IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE
Includes Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection
Weight 16 kg 22 kg 36 kg 41 kg 56 kg 68 kg 71 kg 87 kg
Dimensions (AxBxCxDxE) 240x108x253x80x200 mm 9Ø 240x128x253x100x200 mm 9Ø 300x154x303x145x250 mm 9Ø 300x164x303x155x250 mm 9Ø 360x144x353x122x300 mm 11Ø 360x164x353x142x300 mm 11Ø 360x240x353x172x300 mm 11Ø 360x270x353x202x300 mm 11Ø
Quote / Buy Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
How to buy?

You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.

Related series

TTHW THREE-PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE
TTHW
Rating
From 1000 VA to 10000 VA
Input voltage
400 V
Output voltage
230 V
Protection degree
IP-23 / IK-08
TTH THREE-PHASE CAST RESIN ISOLATION TRANSFORMERS FOR MEDICAL USE
TTH
Rating
From 1000 VA to 10000 VA
Input voltage
400 V
Output voltage
230 V
Protection degree
IP-20

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.