TTHX
Features
Dry type transformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product's lifespan
Safety class I
Includes electrostatic screen between primary and secondary terminals and bimetallic temperature sensor
Includes also lifting eyebolts from X VA
Possibility of tailor-made manufacturing
Downloads
TTHX1 » | TTHX2 » | TTHX3.15 » | TTHX4 » | TTHX5 » | TTHX6.3 » | TTHX8 » | TTHX10 » | |
---|---|---|---|---|---|---|---|---|
Rating | 1000 VA | 2000 VA | 3150 VA | 4000 VA | 5000 VA | 6300 VA | 8000 VA | 10000 VA |
Input voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Output voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Connection group | YNyn0 | YNyn0 | YNyn0 | YNyn0 | YNyn0 | YNyn0 | YNyn0 | YNyn0 |
Protection degree | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 |
Cooling | AN | AN | AN | AN | AN | AN | AN | AN |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Inrush current | < 8In | < 8In | < 8In | < 8In | < 8In | < 8In | < 8In | < 8In |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) | 4,5 kV (1 min, 50 Hz) |
No load voltage | < 3 % | < 3 % | < 3 % | < 3 % | < 3 % | < 3 % | < 3 % | < 3 % |
Leakage current | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) | 0,5 mA (sec-earth) |
Standards | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE | IEC/EN/UNE-EN 61558-2-15, CE |
Includes | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection | Electrostatic screen between 1º & 2º and bimetal thermal protection |
Weight | 16 kg | 22 kg | 36 kg | 41 kg | 56 kg | 68 kg | 71 kg | 87 kg |
Dimensions (AxBxCxDxE) | 240x108x253x80x200 mm 9Ø | 240x128x253x100x200 mm 9Ø | 300x154x303x145x250 mm 9Ø | 300x164x303x155x250 mm 9Ø | 360x144x353x122x300 mm 11Ø | 360x164x353x142x300 mm 11Ø | 360x240x353x172x300 mm 11Ø | 360x270x353x202x300 mm 11Ø |