AUTFX

Features

Dry type autotransformer.

All autotransformers are tropicalized with anti-flash varnish:

  • Protection against corrosive environments.
  • Greater electrical insulation.
  • High compaction power.
  • Noise level reduction.
  • Longer useful life of the product.

Safety class I

Includes lifting bolts from 50 kVA.

Tailor made if the standard specifications are not what is required.

Applications

  • These devices are used to reduce the output voltage of inverters from 800V to 400V. Therefore, achieving the working tension required by the client.
  • If you need other working voltages, they can be manufactured upon request.

Available accessories

  • Class II.
  • Wheels
  • PT100, PTC or Bimetallic probes.
  • C5 paint.
  • Several RAL.
  • Electric temperature panel.
  • Anti-condensation system.
  • IP up to IP-65.

Downloads

Certification

AUTFX1 » AUTFX2 » AUTFX3.15 » AUTFX5 » AUTFX8 » AUTFX10 » AUTFX12.5 » AUTFX16 » AUTFX20 » AUTFX25 » AUTFX31.5 » AUTFX40 » AUTFX50 » AUTFX63 » AUTFX80 » AUTFX100 » AUTFX125 » AUTFX160 » AUTFX200 » AUTFX250 » AUTFX315 » AUTFX400 » AUTFX500 » AUTFX630 » AUTFX800 » AUTFX1000 »
Rating 1 kVA 2 kVA 3,15 kVA 5 kVA 8 kVA 10 kVA 12,5 kVA 16 kVA 20 kVA 25 kVA 31,5 kVA 40 kVA 50 kVA 63 kVA 80 kVA 100 kVA 125 kVA 160 kVA 200 kVA 250 kVA 315 kVA 400 kVA 500 kVA 630 kVA 800 kVA 1000 kVA
Input voltage 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V 800 V
Output voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Connection group YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0 YN0
Protection degree IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Efficiency (%) 95,7 95,8 96,5 96,5 96,7 95,9 96,3 96,6 96,9 94,9 95 95,5 96 96,6 96,8 97,2 97,5 98,2 98,2 98,4 98,5
Noise level (dB) < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 45 < 55 < 55 < 55 < 55 < 55 < 55 < 55 < 55 < 65 < 65 < 65 < 65
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Standards IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE
Weight 5,9 kg 9,5 kg 20 kg 23,9 kg 36 kg 40,4 kg 55 kg 67 kg 78 kg 94 kg 105 kg 125 kg 145 kg 162 kg 191 kg 233 kg 277 kg 320 kg 368 kg 462 kg 560 kg 660 kg 808 kg 1000 kg 1092 kg 1658 kg
Dimensions (AxBxCxDxE) 150x94x178x66x125 mm 6 180x94x203x76x150 mm 6 240x145x253x125x200 mm 9 300x124x303x115x250 mm 9 300x124x303x115x250 mm 9 300x164x303x155x250 mm 9 360x144x353x122x300 mm 11 360x164x353x142x300 mm 11 420x170x419x136x350 mm 11 420x190x419x156x350 mm 11 480x250x480x144x400 mm 11 480x270x480x164x400 mm 11 480x290x480x184x400 mm 11 480x310x480x204x400 mm 11 670x280x615x170x426 mm 13Ø 670x300x615x190x426 mm 13 670x320x690x210x426 mm 13 670x340x690x230x426 mm 13 670x360x690x250x426 mm 13 785x550x880x460x472 mm 17 785x550x880x460x472 mm 17 785x550x880x460x472 mm 17 1016x550x1080x460x690 mm 17 1070x550x1220x460x690 mm 17 1070x550x1220x460x690 mm 17 1300x550x1350x460x800 mm 17
Quote / Buy Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
How to buy?

You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.

Related series

AUTFW THREE-PHASE AUTOTRANSFORMERS FOR SOLAR INVERTERS
AUTFW
Rating
From 1 kVA to 1000 kVA
Input voltage
800 V
Output voltage
400 V
Protection degree
IP-23 / IK-08
AUTFZ THREE-PHASE AUTOTRANSFORMERS FOR SOLAR INVERTERS
AUTFZ
Rating
From 1 kVA to 1000 kVA
Input voltage
800 V
Output voltage
400 V
Protection degree
From IP-65 / IK-10 to IP-54 / IK-10

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.