Single-phase isolation transformers with low inrush (<=5In).
8 kVA Rating

Single-phase isolation transformers with low inrush (<=5In). 8 kVA Rating

TK5INZ8

Technical characteristics

Rating
8 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz
Protection degree
IP-65 / IK-10
Cooling
ANAN
Ambient temperature
45 ºC
Temperature rise
Class F – 155 ºC
Insulation
Class H – 180 ºC
Windings
Class HC – 200 ºC
Inrush current
< 5In
Efficiency (%)
>95%
Noise level (dB)
<40dB
Test voltage
3 kV (1 min, 50 Hz)
Standards
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
Certifications
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
Includes
Bimetal thermal protection
Weight
124 kg
Dimensions (AxBxCxDxE)
745x413x735x370x350mm 11Ø
How to buy?

You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden

Advantages

Dry type transformer.

Efficiency higher than 95%.

Low losses, reducing the consumption of the installation.

Low noise < 40Db

Low connection peak between 3 and 5In, for B or C curve input protection and at its rated current.

Maximum overload 200% 2 seconds.

Finished in anti-flash varnish, by immersion offering:

  • Protection against corrosive environments.
  • Increased electrical insulation.
  • High compacting power.
  • Reduction of the noise level.
  • Increased product life.

Safety class I.

IP-65 up to 16 kVA and IP-54 as from 20 kVA (for IP-65 degree consult us), metal enclosure painted with polyester resin RAL 7035 (cat. C4 ISO 12994-2).

Includes cable glands and silent-blocks.

Possibility of customized manufacture if different specifications than standard are suitable.

Applications

  • TK5IN transformers are used when galvanic isolation is required in single-phase installations.
  • They can be used to switch from Phase-Phase to Phase-Neutral.
  • To disconnect the neutral from earth in those installations with grounded Phase-Neutral.
  • In installations where we have loads that in normal operation have a high level of earth leakage, the TK5IN transformers can isolate them, thus avoiding the untimely jump of the differential.
  • In installations where there may be small voltage peaks or electrical noise, TK5IN transformers help to improve the quality of the signal that feeds the loads.
  • In outdoor installations where weather conditions are adverse, the TK5INZ version with IP-54/65 outdoor use offers an optimum solution.

Available accessories

  • PT100 sensors.
  • Bimetal sensors.
  • PTC sensors.
  • Temperatura control unit.
  • Metal enclosure painted with polyester resin RAL 7035 (cat. C5 ISO 12994-2).

Plans

 Plano de Single-phase isolation transformers with low inrush (<=5In). 8 kVA Rating

Other references in this series

Rating
2 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
2,5 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
3,15 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
4 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
5 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
6,3 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
8 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
10 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
12,5 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
16 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
20 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
25 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
31,5 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Rating
40 kVA
Input voltage
230 V
Output voltage
230 V
Frequency
50/60 Hz

View product »

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.