TTFKW
Features
Dry type transformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product's lifespan
IP-23 metalic box enclosure painted with epoxy polyester resin RAL 7035 (cat. C2 ISO 12994-2)
Safety class I
Neutral sized for 2 x In
Factor K = 13
Includes lifting eyebolts
Possibility of tailor-made manufacturing
Downloads
TTFKW10 » | TTFKW12.5 » | TTFKW16 » | TTFKW20 » | TTFKW25 » | TTFKW31.5 » | TTFKW40 » | TTFKW50 » | TTFKW63 » | TTFKW80 » | TTFKW100 » | TTFKW125 » | TTFKW160 » | TTFKW200 » | TTFKW250 » | TTFKW315 » | TTFKW400 » | TTFKW500 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rating | 10 kVA | 12,5 kVA | 16 kVA | 20 kVA | 25 kVA | 31,5 kVA | 40 kVA | 50 kVA | 63 kVA | 80 kVA | 100 kVA | 125 kVA | 160 kVA | 200 kVA | 250 kVA | 315 kVA | 400 kVA | 500 kVA |
Input voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Output voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
k Factor | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Cover | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) |
THDI (<=) | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 | 0,6 |
Connection group | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 | Dyn11 |
Protection degree | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 |
Cooling | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAF | ANAF |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE |
Weight | 100 kg | 108 kg | 121 kg | 132 kg | 171 kg | 207 kg | 246 kg | 279 kg | 399 kg | 457 kg | 493 kg | 596 kg | 753 kg | 823 kg | 1059 kg | 1269 kg | 1921 kg | 2318 kg |
Dimensions (AxBxCxDxE) | 528x418x644x375x345 mm 12Ø | 597x415x710x375x350 mm 12Ø | 597x415x710x375x350 mm 12Ø | 597x415x710x375x350 mm 12Ø | 597x415x710x375x350 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 970x670x1250x582x470 mm 18Ø | 970x670x1250x582x470 mm 18Ø | 970x670x1250x582x470 mm 18Ø | 1200x760x1555x672x690 mm 18Ø | 1200x760x1555x672x690 mm 18Ø | 1200x760x1555x672x690 mm 18Ø | 1820x1000x1800x900x790 mm 20Ø | 1820x1000x1800x900x790 mm 20Ø |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.