Features

Dry type resin cast transformer

Advantages of resin technology:

  • Protection against corrosive environments
  • Protection against high vibration levels
  • Protection against electrodynamic efforts
  • Reduction of noise level
  • Increase of product's lifespan

​Safety class I

Includes electrostatic screen between primary and secondary terminals and bimetallic temperature sensor

Includes also lifting eyebolts from X VA

Possibility of tailor-made manufacturing

Downloads

TH1000 » TH2000 » TH3150 » TH4000 » TH5000 » TH6300 » TH8000 » TH10000 »
Rating 1000 VA 2000 VA 3150 VA 4000 VA 5000 VA 6300 VA 8000 VA 10000 VA
Input voltage 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V
Output voltage 115-0-115 V 115-0-115 V 115-0-115 V 115-0-115 V 115-0-115 V 115-0-115 V 115-0-115 V 115-0-115 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Protection degree IP-20 IP-20 IP-20 IP-20 IP-20 IP-20 IP-20 IP-20
Cooling AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Inrush current < 8In < 8In < 8In < 8In < 8In < 8In < 8In < 8In
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Test voltage 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz) 3,5 kV (1 min, 50 Hz)
No load voltage < 3 % < 3 % < 3 % < 3 % < 3 % < 3 % < 3 % < 3 %
Leakage current 0,5 A (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth) 0,5 mA (sec-earth)
Standards IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE IEC/EN/UNE-EN 61558-2-15, CE
Includes Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection Electrostatic screen between 1º & 2º and bimetal thermal protection
Weight 21,7 kg 33 kg 34,3 kg 40,2 kg 48 kg 49,2 kg 69,6 kg 82,9 kg
Dimensions (AxBxCxDxE) 190x180x205x115x160 mm 9Ø 200x164x303x155x154 mm 9Ø 240x140x355x112x180 mm 9Ø 240x160x355x122x180 mm 9Ø 240x170x355x142x180 mm 9Ø 280x190x405x126x210 mm 9Ø 280x210x405x146x210 mm 9Ø 280x220x405x156x210 mm 9Ø
Quote / Buy Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
How to buy?

You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.

Related series

THX SINGLE-PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE
THX
Rating
From 1000 VA to 10000 VA
Input voltage
230 V
Output voltage
115-0-115 V
Protection degree
IP-00
THW SINGLE-PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE
THW
Rating
From 1000 VA to 10000 VA
Input voltage
230 V
Output voltage
115-0-115 V
Protection degree
IP-23 / IK-08

Special fabrications

We build transformers and inductive elements tailored to your needs.