PXR
Features
Dry type transformer (IP00)
Full rating in all taps.
Installation on DIN rail (up to 400VA) or by screws.
Custom made following the customer specifications.
Applications
- PXR transformers are specially designed to adapt voltages in switching and control applications in both domestic and industrial environments as well as in electrical cabinets.
- Another important application is the galvanic isolation of installations for safety reasons, as well as the generation of earth-referenced neutrals.
- We can also use them in installations where safety voltages are required (<50V).
Available accessories
Downloads
PXR40 » | PXR63 » | PXR100 » | PXR160 » | PXR200 » | PXR250 » | PXR315 » | PXR400 » | PXR500 » | PXR630 » | PXR800 » | PXR1000 » | PXR1250 » | PXR1600 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rating | 40 VA | 63 VA | 100 VA | 160 VA | 200 VA | 250 VA | 315 VA | 400 VA | 500 VA | 630 VA | 800 VA | 1000 VA | 1250 VA | 1600 VA |
Input voltage | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/400 V | 15/0/15/230/240 V |
Output voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Protection degree | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 | IP-00 |
Cooling | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN | AN |
Ambient temperature | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC | 45ºC |
Temperature rise | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC | Class B – 130ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Test voltage | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth | 4,6 kV (1 min, 50 Hz) pri-sec – 3,2 kV (1 min, 50 Hz) pri-earth – 2,5 kV (1 min, 50 Hz) sec-earth |
Standards | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE |
Mounting | Screws and DIN Rail | Screws and DIN Rail | Screws and DIN Rail | Screws and DIN Rail | Screws and DIN Rail | Screws an DIN Rail | Screws | Screws | Screws | Screws | Screws | Screws | Screws | Screws |
Weight | 0,9 kg | 1,1 kg | 1,4 kg | 2,2 kg | 2,4 kg | 3 kg | 3,8 kg | 4,5 kg | 5,3 kg | 7,3 kg | 8,3 kg | 10,8 kg | 13,1 kg | 16,9 kg |
Dimensions (AxBxCxDxE) | 75x67x89,5x56x62,5 mm 6 | 75x72x89,5x61x62,5 mm 6 | 75x82x89,5x71x62,5 mm 6 | 84x93x102x81x70 mm 6 | 96x88x106x72x80 mm 6 | 96x98x106x82x80 mm 6 | 108x98x109x83x90 mm 6 | 108x108x109x93x90 mm 6 | 126x110x115x75x106 mm 8 | 126x120x115x95x106 mm 8 | 126x130x115x105x106 mm 8 | 150x135x135x102x125 mm 8 | 150x155x135x122x125 mm 8 | 150x175x135x142x125 mm 8 |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.