Features

Dry type transformer

Anti-flash varnish finish, offering:

  • Protection against corrosive environments
  • Increase of electrical isolation
  • High compression capacity
  • Reduction of noise level
  • Increase of product’s lifespan

Safety class I

Includes lifting eyebolts from >10 kVA

Possibility of tailor-made manufacturing

Applications

  • TK transformers are used for the galvanic isolation of single-phase installations in the industrial and tertiary sectors for safety reasons.
  • They are also used in the generation of ground referenced neutrals in high rating single-phase installations.
  • On the other hand, in installations where there may be several earth leakages, TK transformers ensure supply by preventing the tripping of the main differential circuit breaker.
  • To change the neutral regime of the installations, being able to go from a two-phase network to a single-phase network or vice versa (this case implies the generation of the artificial neutral).
  • In installations where there may be small voltage peaks or with a certain level of electrical noise, the use of a transformer helps to improve the quality of the electrical network in its secondary.
  • In outdoor installations where weather conditions are adverse, the TKZ version with IP-54 external enclosure offers an optimal solution.

Available accessories

  • PT100 probe.
  • PTC probe.
  • Bimetallic probe.
  • Temperature control unit

TKX3.15 » TKX4 » TKX5 » TKX6.3 » TKX8 » TKX10 » TKX12.5 » TKX16 » TKX20 » TKX25 » TKX31.5 » TKX40 » TKX50 »
Rating 3,15 kVA 4 kVA 5 kVA 6,3 kVA 8 kVA 10 kVA 12,5 kVA 16 kVA 20 kVA 25 kVA 31,5 kVA 40 kVA 50 kVA
Input voltage 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V
Output voltage 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Protection degree IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Insulation Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC Class H – 180 ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Standards IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 61558, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 60076, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
IEC/EN/UNE-EN 60076, CE
UL 5085-1 / UL 5085-2
CAN/CSA C22.2 No 66.1-06, CAN/CSA C22.2 No 66.2-06
Certifications UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
UL RECOGNIZED – CONSTRUCTION ONLY – Component
FILE: E532753
Weight 26 kg 30 kg 38 kg 48 kg 59 kg 64 kg 67 kg 80 kg 93 kg 108 kg 136 kg 166 kg 193 kg
Dimensions (AxBxCxDxE) 200x167x321x128x154 mm 9Ø 240x145x381x108x180 mm 11Ø 240x165x381x128x180 mm 11Ø 280x244x366x126x210 mm 11Ø 280x264x366x146x210 mm 11Ø 320x239x418x126x240 mm 11Ø 320x239x418x126x240 mm 11Ø 320x259x418x146x240 mm 11Ø 320x279x418x166x240 mm 11Ø 320x299x418x186x240 mm 11Ø 440x322x559x156x250 mm 11Ø 440x342x559x176x250 mm 11Ø 440x362x559x196x250 mm 11Ø
Downloads
Quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
Buy Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart
How to buy?

You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden

Related series

TKW SINGLE-PHASE ISOLATION TRANSFORMERS
TKW
Rating
From 3,15 kVA to 50 kVA
Input voltage
230 V
Output voltage
230 V
Protection degree
IP-23 / IK-08
TKZ SINGLE-PHASE ISOLATION TRANSFORMERS
TKZ
Rating
From 3,15 kVA to 50 kVA
Input voltage
230 V
Output voltage
230 V
Protection degree
From IP65 – IK-10 to IP54 – IK-10
TKE SINGLE-PHASE CAST RESIN ISOLATION TRANSFORMERS
TKE
Rating
From 3,15 kVA to 50 kVA
Input voltage
230 V
Output voltage
230 V
Protection degree
From IP-20 to IP-00

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.