Features

Dry type resin cast transformer

Advantages of resin technology::

  • Protection against corrosive environments.
  • Protection against high vibration levels.
  • Protection against electrodynamic efforts.
  • Reduction of noise level.
  • Increase of productʼs lifespan

Safety class I.

Includes lifting eyebolts from 6,3 kVA.

Possibility of tailor-made manufacturing.

Applications

  • TT transformers are used for insulation galvanic three-phase installations for reasons of security.
  • They are also used in the generation of neutrals referenced to ground in single-phase installations of high power.
  • In facilities where there may be small peaks of voltage or noise, the TT transformers help improve the quality of the signal that feeds the charges.
  • On the other hand in facilities where there may be several leakage to ground, TT transformers ensure the supply avoiding the tripping of the differential switch general.

Available accessoires

  • Protections in primary and secondary.
  • One, two and up to 3 electrostatic screens.
  • Class II
  • Wheels.
  • PT100, PTC or Bimetallic probes.
  • Painting C5.
  • Different RAL.
  • Temperature control unit
  • Anti condensation system
  • Different IP up to IP-65

CE Certificate

TTE0.4 » TTE0.63 » TTE1 » TTE1.6 » TTE2 » TTE2.5 » TTE3.15 » TTE4 » TTE5 » TTE6.3 » TTE8 » TTE10 » TTE12.5 » TTE16 » TTE20 » TTE25 » TTE31.5 » TTE40 » TTE50 » TTE63 » TTE80 » TTE100 » TTE125 » TTE160 » TTE200 » TTE250 » TTE315 » TTE400 »
Rating 0,63 kVA 0,63 kVA 1 kVA 1.6 kVA 2 kVA 2,5 kVA 3,15 kVA 4 kVA 5 kVA 6,3 kVA 8 kVA 10 kVA 12,5 kVA 16 kVA 20 kVA 25 kVA 31,5 kVA 40 kVA 50 kVA 63 kVA 80 kVA 100 kVA 125 kVA 160 kVA 200 kVA 250 kVA 315 kVA 400 kVA
Input voltage 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Output voltage 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N 400 V+N
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Connection group Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0 Yyn0
Protection degree IP-20 IP-20 IP-20 IP-20 IP-20 IP-20 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00 IP-00
Cooling AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Ambient temperature 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC 45 ºC
Temperature rise Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class F – 155ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Insulation Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC Class H – 180ºC
Windings Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC Class HC – 200 ºC
Test voltage 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz) 3 kV (1 min, 50 Hz)
Standards IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 61558, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE IEC/EN/UNE-EN 60076, CE
Weight 7,7 kg 10 kg 15 kg 24 kg 28 kg 33 kg 36 kg 47 kg 51 kg 58 kg 73 kg 99 kg 116 kg 139 kg 159 kg 184 kg 205 kg 321 kg 374 kg 421 kg 471 kg 569 kg 642 kg 782 kg 1083 kg 1216 kg 1487 kg 1635 kg
Dimensions (AxBxCxDxE) 160x92x183x51x125 mm 7Ø 160x111x183x66x125 mm 7Ø 190x104x208x76x150 mm 7Ø 280x158x205x100x250 mm 9Ø 250x153x268x125x200 mm 9Ø 310x134x326x102x250 mm 9Ø 310x144x326x112x250 mm 9Ø 310x164x326x132x250 mm 9Ø 310x174x326x142x250 mm 9Ø 370x155x381x122x300 mm 11Ø 370x175x381x142x300 mm 11Ø 430x258x366x140x350 mm 11Ø 430x278x372x162x350 mm 11Ø 490x258x459x126x400 mm 11Ø 490x278x459x146x400 mm 11Ø 490x318x459x166x400 mm 11Ø 490x338x459x186x400 mm 11Ø 714x345x650x170x426 mm 11Ø 714x365x650x190x426 mm 11Ø 714x385x650x210x426 mm 11Ø 770x560x873x460x470 mm 17Ø 770x560x823x460x470 mm 17Ø 770x560x823x460x470 mm 17Ø 770x560x823x460x470 mm 17Ø 1026x560x823x460x690 mm 13Ø 1026x560x1058x460x690 mm 13Ø 1093x560x1198x460x690 mm 17Ø 1093x560x1198x460x690 mm 17Ø
Quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote Add to quote
Buy Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart Add to cart
How to buy?

You can see the prices and buy online if you are registered and located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden

Related series

TTX THREE-PHASE ISOLATION TRANSFORMERS
TTX
Rating
From 0,63 kVA to 1000 kVA
Input voltage
400 V
Output voltage
400 V+N
Protection degree
IP-00
TTW THREE-PHASE ISOLATION TRANSFORMERS
TTW
Rating
From 0,63 kVA to 1000 kVA
Input voltage
400 V
Output voltage
400 V+N
Protection degree
IP-23 / IK-08
TTZ THREE-PHASE ISOLATION TRANSFORMERS
TTZ
Rating
From 0,63 kVA to 1000 kVA
Input voltage
400 V
Output voltage
400 V+N
Protection degree
From IP65 – IK-10 to IP54 – IK-10

Special fabrications

We build transformers and inductive elements tailored to your needs.

Explain your needs and our engineers will create a solution adapted to your company.