TTDW
Features
Dry type transformer
Anti-flash varnish finish, offering:
- Protection against corrosive environments
- Increase of electrical isolation
- High compression capacity
- Reduction of noise level
- Increase of product’s lifespan
Metalic box IP-23 enclosure painted with Polyester resin RAL 7035 (cat. C3 ISO 12994-2)
Safety class I
Includes lifting eyebolts from >6,3 kVA
Possibility of tailor-made manufacturing
Applications
- TTD transformers are mainly used to isolate circuits, raising the voltage from 230V to 400V
- TTU transformers can be used to increase voltage from 230V to 400V
- Changing the neutral system of an installation
- In installations with a certain level of electrical noise, the TTD series improves the quality of the secondary electrical network
Available accessories
- Protections in primary and secondary.
- One, two and up to 3 electrostatic screens.
- Class II
- Wheels.
- PT100, PTC or Bimetallic probes.
- Painting C5.
- Different RAL.
- Temperature control unit
- Anti condensation system
- Different IP up to IP-65
CE certificate
TTDW0.63 » | TTDW1 » | TTDW2 » | TTDW2.5 » | TTDW3.15 » | TTDW4 » | TTDW5 » | TTDW6.3 » | TTDW8 » | TTDW10 » | TTDW12.5 » | TTDW16 » | TTDW20 » | TTDW25 » | TTDW31.5 » | TTDW40 » | TTDW50 » | TTDW63 » | TTDW80 » | TTDW100 » | TTDW125 » | TTDW160 » | TTDW200 » | TTDW250 » | TTDW315 » | TTDW400 » | TTDW500 » | TTDW630 » | TTDW1000 » | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rating | 0,63 kVA | 1 kVA | 2 kVA | 2,5 kVA | 3,15 kVA | 4 kVA | 5 kVA | 6,3 kVA | 8 kVA | 10 kVA | 12,5 kVA | 16 kVA | 20 kVA | 25 kVA | 31,5 kVA | 40 kVA | 50 kVA | 63 kVA | 80 kVA | 100 kVA | 125 kVA | 160 kVA | 200 kVA | 250 kVA | 315 kVA | 400 kVA | 500 kVA | 630 kVA | 1000 kVA |
Input voltage | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V | 400 V |
Output voltage | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V | 230 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Connection group | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 | Yyn0 |
Cover | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) | Metal enclosure RAL 7035 (cat. C3 ISO 12994-2) |
Protection degree | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 | IP-23 / IK-08 |
Cooling | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAN | ANAF | ANAF | ANAF |
Ambient temperature | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC | 45 ºC |
Temperature rise | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class F – 155ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Insulation | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC | Class H – 180ºC |
Windings | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC | Class HC – 200 ºC |
Efficiency (%) | 88,7 | 90,5 | 93,5 | 94,7 | 94,7 | 95,4 | 95,7 | 95,8 | 96,5 | 96,5 | 96,7 | 95,9 | 96,3 | 96,6 | 96,9 | 94,9 | 95 | 95,5 | 96 | 96,6 | 96,8 | 97,2 | 97,5 | 98,2 | 98,2 | 98,4 | 98,5 | 98,6 | 99 |
Noise level (dB) | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 45 | < 55 | < 55 | < 55 | < 55 | < 55 | < 55 | < 55 | < 55 | < 65 | < 65 | < 65 | < 65 | < 65 | < 65 |
Test voltage | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) | 3 kV (1 min, 50 Hz) |
Standards | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 61558, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE | IEC/EN/UNE-EN 60076, CE |
Weight | 7,6 kg | 13,2 kg | 24,8 kg | 28,8 kg | 32,8 kg | 40,8 kg | 45,2 kg | 61 kg | 73 kg | 89 kg | 106 kg | 117 kg | 137 kg | 157 kg | 174 kg | 237 kg | 279 kg | 323 kg | 366 kg | 414 kg | 514 kg | 612 kg | 754 kg | 855 kg | 1093 kg | 1185 kg | 1808 kg | 2149 kg | 3143 kg |
Dimensions (AxBxCxDxE) | 194x175x220x165x100 mm 6Ø | 240x190x250x180x150 mm 6Ø | 315x230x315x205x200 mm 6Ø | 385x260x384x245x250 mm 6Ø | 385x260x384x245x250 mm 6Ø | 385x260x384x245x250 mm 6Ø | 385x260x384x245x250 mm 6Ø | 458x340x500x300x300 mm 12Ø | 458x340x500x300x300 mm 12Ø | 528x418x644x375x345 mm 12Ø | 528x418x644x375x345 mm 12Ø | 597x415x710x375x350 mm 12Ø | 597x415x710x375x350 mm 12Ø | 597x415x710x375x350 mm 12Ø | 597x415x710x375x350 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 795x550x970x500x415 mm 12Ø | 970x670x1250x582x470 mm 18Ø | 970x670x1250x582x470 mm 18Ø | 970x670x1250x582x470 mm 18Ø | 1200x760x1555x672x690 mm 18Ø | 1200x760x1555x672x690 mm 18Ø | 1200x760x1555x672x690 mm 18Ø | 1820x1000x1800x900x790 mm 20Ø | 1820x1000x1800x900x790 mm 20Ø | 1820x1000x1800x900x790 mm 20Ø |
Quote / Buy |
How to buy?
You can buy online if you are located in one of this countries: Austria, Croatia, Czech Republic, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Lithuania, Luxembourg Poland, Slovakia and Sweden.
Related series
Special fabrications
We build transformers and inductive elements tailored to your needs.
Explain your needs and our engineers will create a solution adapted to your company.